KASON-RMD300E MDR Moving Die Rheometer

KASON-RMD300E MDR Moving Die Rheometer

Rotorless vulcanization instrument is the most widely used instrument in rubber processing industry to control rubber quality, rapid inspection and rubber basic research, which provides accurate data for rubber optimization formula combination, and can accurately measure the scorch time, positive vulcanization instrument time, vulcanization index and maximum and minimum torque parameters.

Request a Quote

Product Details


Equipment overview:

Rotorless vulcanization instrument is the most widely used instrument in rubber processing industry to control rubber quality, rapid inspection and rubber basic research, which provides accurate data for rubber optimization formula combination, and can accurately measure the scorch time, positive vulcanization instrument time, vulcanization index and maximum and minimum torque parameters.


Standards:

The rotor-free vulcanization test instrument meets the requirements of GB/T16584 "Rubber - Determination of vulcanization characteristics with rotor-free vulcanization instrument", ISO6502 requirements and the data of T10, T30, T50, T60 and T90 required by Italian standards. ASTM-D5289, ISO-6502.



Product parameters

Temperature control range

Room temp—200℃

Temperature fluctuation range

±0.15℃

Torque resolution

1/500000

Torque accuracy

0.3%

Torque unit

N.mN.cmN.inchkN.mkN.cmkN.inchkg.mkg.cmkg.inchlp.mlp.cmlp.inchg.mg.cmg.inch

Temperature display resolution

0.01℃

Temperature recovery time after closing

< 1.5min

Temperature unit

C (Celsius), F (Fahrenheit), K (Kelvin)

Acquisition rate

200 times per second

Support language

English, Simplified Chinese, Traditional Chinese.

Standard of use

GB/T 16584ASTM D5289ISO 6502

Calculation parameter

ts1ts2t10t30t50t70t90Vc1Vc2

Software interface

USB2.0

Print content

Date, time, temperature, vulcanization curve, temperature curve, ML, MH, ts1, ts2, t10, t50, t90, Vc1, Vc2

Test standard

Conforms to ASTM D 5289, ISO6502

Oscillation frequency

100 cycles per minute (1.67Hz)

Amplitude of oscillation

Standard: ±1 degree ±0.03 degree

[Optional] ±0.5 degrees ±0.03 degrees, ±3 degrees ±0.03 degrees

Temperature change time

170℃→190℃ within 55 seconds at ±0.3℃

Reheating time after film closing

190 ° C →170 ° C within 1 minute and 40 seconds and at ±0.3 ° C

Rate of warming

The temperature compensation returns to the set temperature of 170 ° C (error within ±0.3 ° C) in no more than 30±3 seconds

Power source

220VAC±10%, 50±3Hz;

Air pressure source

minimum 65psi (4.5kg/cm2)

dimension

L65cm x W59cmx H148cm