Nosed Rockwell,Superficial Rockwell Hardness Tester

Nosed Rockwell,Superficial Rockwell Hardness Tester

he specially designed indenter is extended horizontally, which can measure the parts that are unable to be measured by the general hardness tester, such as ring and tube, with the minimum test inner diameter of 25mm

Request a Quote

Product Details

Product Introduction: 
1.The specially designed indenter is extended horizontally, which can measure the parts that are unable to be measured by the general hardness tester, such as ring and tube, with the minimum test inner diameter of 25mm
2.Adopting electric loading, high precision sensor, closed loop control system.
3.Touch screen interface, easy to operate, directly select the hardness scale, the force value is automatically changed in the test parameters.
4.The test force can be modified automatically by standard dynamometer.
5.Auto-loading main test force
6.The data processing function is powerful, including: HR, HB, HV and other hardness type conversion, setting up the qualified range, automatic alarm for over-limit, and inputting the information such as tester, sample name, etc.
7. Measurement data U disk saved in EXCEL format, easy to edit and process.

Product parameters

Model

KASON HTR-150/45NT

Rockwell initial test force

10kgf(98.07N)

Superficial Rockwell initial test force

3.0kgf(29.4N)

Rockwell total test force

60kgf(588N)   100kgf(980N)    150kgf(1471N)

Superficial Rockwell total test force

15kgf(147.1N)   30kgf(249.2N)    45kgf(441.3N)

Rockwell hardness scale

HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、 HRL、HRM、HRR、HRP、HRS、HRV    

Superficial Rockwell hardness scale

15N、15T、15W、15X、15Y、30N、30T、30W、30X、30Y、45N、45T 、45W、45X、45Y

Rockwell measurement range

HRA:20-88、HRB:20-100 、HRC:20-70 、HRD:40-77 、HRE:70-100 、HRF:60-100 、HRG:30-94、HRH:80-100、HRK:40-100、HRL:100-120  HRM:85-115、 HRR:114-125

Superficial Rockwell measurement range

HR15N:70-94 HR30N:42-86 HR45N:20-77

HR15T:67-93 HR30T:29-82 HR45T:1-72

Test force dwell time

0-99s

Hardness resolution

0.1HR

Force error

<1.0%

Data output

LCD display

Data storage

The measured values are stored in the U disk in EXCEL format

Conversion scale

Brinell, Vickers

Carried standard

BSEN 6508, ISO 6508, ASTM E18, GB/T230

Maximum allowable specimen height

300mm

Distance from indenter to wall

250mm

Size

720×260×840mm

Weight

80kg

Package size

900*480*990mm

Gross weight

113kg

Power supply

AC220+5%,50~60Hz

Download

Name Download

Applicable industries

Related Products