KASON-DG-M Integrated test bench

KASON-DG-M Integrated test bench

This drip irrigation system is used for hydraulic performance testing of drippers and drip irrigation tubing (tape).

Request a Quote

Product Details

Overview

This drip irrigation system is used for hydraulic performance testing of drippers and drip irrigation tubing (tape). It meets the technical requirements for hydraulic performance testing of drippers and drip irrigation tubing (tape) in GB/T17187-2009 "Agricultural Irrigation Equipment - Technical Specifications and Test Methods for Drippers and Drip Irrigation Tubing", GB/T19812.1-2017 "Plastic Water-Saving Irrigation Equipment - Single-Wing Labyrinth Drip Irrigation Tape", GB/T19812.2-2017 "Plastic Water-Saving Irrigation Equipment - Pressure Compensating Drippers and Drip Irrigation Tubing", GB/T19812.3-2017 "Plastic Water-Saving Irrigation Equipment - Embedded Drip Irrigation Tubing and Drip Irrigation Tape", and industry standards SL/T67.1-94 "Micro Irrigation Emitter - Dripper", SL/T67.2-94 "Micro Irrigation Emitter - Drip Irrigation Tubing", and QB/T2517-2001 "Disposable Plastic Drip Irrigation Tape".

 

The test items include:

Hydrostatic pressure resistance test at ambient temperature;

Hydrostatic pressure resistance test at high temperature;

Flow uniformity test;

Pressure-flow relationship test; and burst test.

It can also meet the requirements for the "pressure loss-flow relationship test".

 

The high-temperature test chamber mainly provides a constant temperature test environment for tests requiring high-temperature hydrostatic pressure resistance, and a safe location for burst tests.

Product parameters

Hydraulic Performance Test Bench for Drip Heads and Drip Irrigation Pipes (Belts)

Dimensions: (2880*1290*1260)       Voltage: 220V @50HZ 5A

Test Stations

25 (Drip Heads or Drip Irrigation Units)

Test Methods

Closed-Circuit Method, Loop Method

Automatic Measurement Units

25 Points

Measurement Range

0-2L(2000g)

Measurement Accuracy

≤0.5%FS

Resolution

0.1mL (g)

Applicable Drip Element Spacing

100mm-500mm (Expandable)

Minimum Timing Unit

0.1s

Constant Temperature Water Supply Pressurization System

Dimensions: (1250*700*1000)      Voltage: 380V @50HZ 60A

Pressure Range

10kPa1000kPa; Resolution: 0.1kPa

Pressure control accuracy

≤1%FS

Constant temperature

Room temperature40℃; Constant temperature accuracy: ±1℃

Heating power

3 kw

Refrigeration unit (optional item not included in the quotation)

1 kw

High temperature test chamber

Dimensions: (3600*702*1020) Voltage: 380V @50HZ 30A

Test stations

5

Constant temperature

Room temperature70℃

Constant temperature accuracy

±1℃

Heating power

9 kw

Relay control system and software

Includes one control cabinet, one set of dedicated control software, one Lenovo computer, and one HP printer