This machine is suitable for measuring the shear rate of plastics and polymer materials and the fluidity of the melt under shear stress at a certain temperature, including the apparent viscosity of thermoplastics and thermosetting materials.
Request a Quote3、Different specifications (low temperature type, high temperature type, different pressures, different rod diameters, etc.) can be customized according to user requirements.This machine has a high pressure、double rod single pressure head、frame H-type structure.
The dynamic measurement and control capillary rheometer developed by our company has the following characteristics:
1、High data collection frequency (greater than 100PPS), can more accurately record the transition points of materials in different states without missing the key material state transition points; accurately calculate the apparent viscosity at different shear rates.
2、Can achieve the superposition of multiple data curve and display coordinates in various curve forms.
3、The load loading device of the instrument is designed reasonably, using high-precision pressure sensors for data acquisition, eliminating the traditional load sensor acquisition; Dual closed loop of software and hardware, achieving stepless adjustment of speed and loading force; Manual and automatic loading control can be used, which is convenient, fast, and accurate. Inductive manual displacement adjustment;
4、Regarding the coordinate axes of shear viscosity and shear rate curves: During the test, the coordinate axis is the normal coordinate axis. When the test is over, if you want to view the log coordinate axis image, you can directly adjust it with the mouse. So that you can observe the image in two ways, and the lowest point of the coordinate axis is set with the mouse after the test.
5、The whole machine adopts a frame-type aluminum alloy structure, which has a more beautiful appearance, stronger stability and is easier to transport and install.
6、Scalability: This instrument can be expanded into a wire drawing instrument without replacing the host.
|
Parameter |
Value |
|
Temperature Range |
Room temperature ~ 400℃ (Can be customized according to customer requirements, price negotiable) |
|
Heating Rate |
1-6℃/min, continuously adjustable with rapid heating function |
|
Temperature Measurement Display Accuracy |
0.1℃ |
|
Pressure Range |
1-100MPa ±0.5% (Can be customized according to customer requirements, price negotiable) |
|
Maximum Driving Force |
20kN (50kN can be customized according to customer requirements, price negotiable) |
|
Pressure Measurement Accuracy |
±0.5% FS |
|
Pressure Resolution |
0.1MPa |
|
Velocity Range |
0.01-500mm/min |
|
Deformation Measurement Accuracy |
±0.5% FS |
|
Plug Diameter |
φ12 mm (Can be customized according to customer requirements, price negotiable) |
|
Plug Area |
113.04mm² |
|
Discharge Die Specification |
Ø 1×5 mm, Ø 1×10 mm, Ø 1×20 mm, Ø 1×40 mm (Can be customized according to customer requirements, price negotiable) |
|
Discharge Die Material |
Tungsten carbide |
|
Power Supply |
AC220V, 50Hz, power < 1000W |
|
Overall Equipment Dimensions (L×W×H) |
620×530×2000 mm |