KS-TY9000 is Full Range of Solutions for the Entire Metals Industry. It use full-digital technology to replace bulky photo multiplier tube (PMT) simulation technology and keep pace with international spectrometer technology
Request a Quote1. Summary
KS-TY9000 is Full Range of Solutions for the Entire Metals Industry. It use full-digital technology to replace bulky photo multiplier tube (PMT) simulation technology and keep pace with international spectrometer technology. The adoption of vacuum optical chamber design, full-digital excitation light source, advanced CCD detectors, and high-speed data readout system equips the device with high properties, ultra-low limit of detection (LOD), long-term stability and repeatability. The analytical precision can meet the requirements of laboratory standard, the analytical date is stable and reliable. Widely used in Metallurgy, casting, machinery processing and other industries incoming and outgoing product quality control.
2. Supply list
|
No. |
Item |
Specifications |
QTY |
Unit |
Remarks |
|
1 |
Optical Emission Spectrometer |
KS-TY9000 |
1 |
Set |
Include in quotation. |
|
2 |
Business computer |
|
1 |
Set |
|
|
3 |
Printer |
|
1 |
Set |
|
|
4 |
Tungsten electrode |
|
1 |
Pc |
|
|
5 |
Electrode pressure spring |
|
1 |
Pc |
|
|
6 |
The electrode fixed screw |
|
2 |
Pcs |
|
|
7 |
Electrode brush |
Φ6 |
2 |
Pcs |
|
|
8 |
Lens holder sealing ring |
Φ16×2.65 |
2 |
Pcs |
|
|
9 |
Lens holder sealing ring |
Φ72×2.65 |
1 |
Pc |
|
|
10 |
Exhaust gas filter core |
|
1 |
Pc |
|
|
11 |
Degreasing cotton |
|
15 |
G |
|
|
12 |
Power socket |
|
1 |
Pc |
|
|
13 |
M2 Internal hexagonal wrench |
|
1 |
Set |
|
|
14 |
M4 Internal hexagonal wrench |
|
1 |
Set |
|
|
15 |
Long handle phillips screwdriver |
|
1 |
Pc |
|
|
16 |
13-15 fixed wrench |
|
1 |
Pc |
|
|
17 |
Spark machine screw |
M6 |
4 |
Pcs |
|
|
18 |
Fuse |
10A |
2 |
Pcs |
|
|
19 |
Argon gas pressure reducing valve |
|
1 |
Pc |
|
|
20 |
Argon gas pipeline |
|
2 |
M |
|
|
21 |
Exhaust pipe |
|
1 |
Pc |
|
|
22 |
Gas bottle |
|
2 |
Pcs |
|
|
23 |
Print paper |
|
1 |
Pc |
|
|
24 |
Spectrometer manual |
|
1 |
Set |
OES Analytical Program
|
No |
Elements |
Low Alloy Steel |
Cast Iron |
|
1 |
C |
0.006-1.6 |
1.81-4.5 |
|
2 |
Si |
0.0014-2.57 |
0.15-3.96 |
|
3 |
Mn |
0.021-19.74 |
0.114-3.42 |
|
4 |
P |
0.0032-0.135 |
0.021-0.82 |
|
5 |
S |
0.0013-0.111 |
0.003-0.211 |
|
6 |
Cr |
0.002-12.42 |
0.03-2.5 |
|
7 |
Ni |
0.0107-4.0 |
0.01-4.77 |
|
8 |
Mo |
0.004-3.98 |
0.003-1.7 |
|
9 |
Al |
0.003-1.29 |
0.002-0.214 |
|
10 |
Cu |
0.0032-0.7 |
0.06-1.73 |
|
11 |
Co |
0.0088-0.5 |
0.0046-0.14 |
|
12 |
Ti |
0.001-0.297 |
0.004-0.5 |
|
13 |
Nb |
0.0057-0.506 |
0.003-0.33 |
|
14 |
V |
0.0082-1.26 |
0.0014-1.13 |
|
15 |
W |
0.05-1.97 |
0.001-0.97 |
|
16 |
Mg |
|
0.0001-0.1 |
|
17 |
B |
0.0017-0.0083 |
0.002-0.26 |
|
18 |
Sn |
0.0035-0.054 |
0.0007-0.563 |
|
19 |
Zn |
0.002-0.04 |
0.001-0.0055 |
|
20 |
As |
0.0019-0.056 |
0.002-0.26 |
|
21 |
Bi |
0.0002-0.013 |
0.0017-0.05 |
|
22 |
Zr |
0.005-0.41 |
|
|
23 |
La |
|
0.0002-0.023 |
|
24 |
Ca |
0.0001-0.055 |
|
|
25 |
Ce |
0.0002-0.019 |
0.0002-1.81 |
|
26 |
Sb |
0.0004-0.01 |
0.004-0.2 |
|
27 |
Fe |
Reference |
Reference |
Notes:
1. The elements highlighted in orange are available normally, those in blue can be added according to the standard sample available or not.
2. The analysis curves highlighted in green can be added according to current stand samples in the markets, those highlighted in orange are available normally, and it can meet 80% customer’s need.
3. Numbers of Elements added or channels are depended on the price.
4. For special material beyond the detection range of elements and measurement, buyer and supplier can make a decision on the internal control standard.
5. Due to the lag of the national standard material, the elements will be carried out according the original standard before new material coming out.
3. Technical Data of KS-TY9000
|
Item |
Index |
|
|
Optical System |
Focal Length |
400mm |
|
Wavelength range |
165~589nm (Extendable) |
|
|
Detector |
High resolution CCD Multi detectors |
|
|
Degree of vacuum |
Auto control within 6-20 pa |
|
|
Pixel resolution |
30pm |
|
|
Grating line |
2400m1/mm |
|
|
First order spectral line dispersion rare |
1.2nm/mm |
|
|
Average resolution ratio |
10pm/pixel |
|
|
Full spectrum |
||
|
Light room temperature is controlled automatically |
||
|
Spark Source |
Type |
Digital arc and spark source |
|
Spark frequency |
100-1000HZ |
|
|
Discharge current |
1-400A |
|
|
Ignition voltage |
>15000V |
|
|
Excitation light |
Optimization of discharge parameters design |
|
|
High energy precombustion technology HEPS |
||
|
Processor |
High-speed data synchronization acquisition and processing |
|
|
Spark Stand |
Electrode |
Tungsten electrode technology |
|
Make up |
Thermal deformation self-compensation design |
|
|
Argon flushed with minimal consumption of Argon |
||
|
Spray discharge electrode technology |
||
|
Adjustable electrode technology |
||
|
Others |
Measurable elements |
Fe、Al、Cu、Ni、Ti、Co、Zn、Sn、Mg、Pb etc |
|
Dimension |
800mm(L)*700mm*470mm(H) |
|
|
weight |
About 100kg |
|
|
Storage temperature |
0℃-45℃ |
|
|
Operating temperature |
10℃-35℃, 23±2℃ is recommended |
|
|
Power |
AC220V/50Hz(Customized) |
|
|
Power consumption |
Excitation:700W/Stand by:100W |
|
|
Argon quality |
99.999%, Argon pressure>4Mpa |
|
|
Argon consumption |
5L/min during spark mode |
|
|
Interface |
Ethernet data transmission based on DM9000A |
|
| Name | Download |
|---|---|
| KS-TY9000 Optical Emission Spectrometers .pdf |